PDF 原檔:報告_OCP2026_劍橋_光寶科_銅燒結BGA電遷移_20261015_original.pdf
講者公開簡報(OCP 官方 Recorded Content 頁提供下載)。文字以 PyMuPDF 逐頁抽取,
### p<n>為頁碼;圖表內容見原檔。
圖片清單(已驗證 2026-10-19)
| 檔名 | 頁 | 分類 | 親眼所見內容 |
|---|---|---|---|
報告_OCP2026_劍橋_光寶科_銅燒結BGA電遷移_20261015_p2.png |
p2 | 真資料圖 | 問題陳述:XPU 水平/垂直供電兩種 BGA 位置示意,註電流密度預期超過 2 A/mm2;右為焊料 BGA 在 96h、120h 陰極側出現裂縫的剖面電鏡圖 |
報告_OCP2026_劍橋_光寶科_銅燒結BGA電遷移_20261015_p4.png |
p4 | 真資料圖 | 銅燒結 BGA 製程(銅膏點膠、100C/20min N2 乾燥、220C/5min 加 10MPa 燒結、剪切測試,電阻分布約 21-25 mΩ)與 4 樣品串接電遷移測試台,電流密度 50A/mm2 |
報告_OCP2026_劍橋_光寶科_銅燒結BGA電遷移_20261015_p5.png |
p5 | 真資料圖 | 電壓對時間曲線:SAC305 焊點 5 個樣品約 260-325h 開路失效(準則約 0.38V),燒結銅 5 個樣品至 900h 電壓持平約 0.21-0.23V |
原始內容
p1
Cu Sintering BGA Interconnect for Mitigating Electromigration in High-Current AI Power Delivery Chengjie Du, Xufu Ren Department of Engineering, University of Cambridge
p2
Problem Statement BGA application in high-current AI power delivery Solder: Electromigration failure current density expected to surpass 2 A/mm2
p3
Proposed solution: Cu sintering Cu nanoparticles sintering Daisy-chained interconnects for comparing electromigration reliability of soldering and Cu sintering
p4
Proposed solution: Cu sintering Fabrication process and performance evaluation of sintered-Cu BGA interconnect Current density: 50A/mm2
p5
Proposed solution: Cu sintering Sintered-Cu BGA interconnects provide significant electromigration reliability improvement compared to solder-based counterpart Under current density of 50 A/mm2, SAC305 exhibits open-circuit failure at 300 h, Sintered-Cu BGA maintains stable electrical conduction for more than 900 h
p6
Proposed solution: Cu sintering Open-circuit failure of SAC305 BGA interconnect: crack formation and growth at Cathode
p7
Proposed solution: Cu sintering Microstructure of sintered Cu remain unchanged, showing that Cu atoms migration was negligible. This microstructural stability is consistent with the stable electrical conduction
p8
Proposed solution : Cu sintering For SAC305 at 300 h of EM testing, significant atomic concentration occurs at anode interface. In contrast, atomic concentration of sintered Cu interconnect shows negligible variation at 900 h of EM testing.
p9
Next steps Large area with hundreds of Cu sintering BGA interconnects fabrication
p10